What Is the VTI-GL-100C Distributed Temperature Sensing (DTS) System?
Direct Engineering Summary: The VTI-GL-100C DTS is a 4-channel Raman OTDR fiber optic distributed temperature sensing system manufactured by VTI Corp (MST: 0107921571) and always supplied with VTI Red Optical Fiber. It delivers continuous linear thermal profiling up to 20 km (5 km/channel) with ±1.0 °C accuracy, 0.5 m spatial resolution, 16 alarm relays, and Modbus TCP / RS485 SCADA telemetry for 110kV–500kV cables and transformers.
Core Engineering Highlights
- Mandatory Paired System: Supplied as a unified kit comprising the wall-mount
VTI-GL-100Ccontroller + VTI Red Optical Sensing Fiber. - 100% EMI & High-Voltage Immunity: Passive quartz optical fiber contains zero metal conductors, immune to
500 kVelectromagnetic interference and partial discharge. - Pinpoint Hotspot Localization:
0.5 mspatial sampling resolution and1.0 malarm zone resolution across up to20 kmtotal route length. - Autonomous Local HMI & Protection Relays: Integrated
10.4-inchindustrial touchscreen, 4 front-panel status lamps (Run,Fault,Pwr,Alarm), and16programmable dry-contact relays (250 VAC / 3 A) for direct breaker inter-tripping or fire-suppression activation.
Complete HTML Technical Datasheet — VTI-GL-100C DTS & VTI Red Optical Fiber
Datasheet Specification Summary: Below is the open, crawlable HTML technical specification table for the VTI-GL-100C Distributed Temperature Sensing Controller and its paired VTI Red Optical Fiber, covering optical range (4 × 5 km), metrology accuracy (±1.0 °C), spatial resolution (0.5 m), relay capacity (16 channels), and SCADA protocols (Modbus TCP Port 502, RS485 Modbus RTU).
| Specification Parameter | VTI-GL-100C DTS Technical Value | Engineering Standard / Notes |
|---|---|---|
| Model & Manufacturer | VTI-GL-100C (Supplied with VTI Red Optical Fiber) |
Viet Technology and Investment Corporation JSC (VTI Corp — MST: 0107921571) |
| Optical Sensing Principle | Raman Backscatter Optical Time-Domain Reflectometry (OTDR) | Intrinsically passive optical fiber, 100% immune to HV EMI/RFI |
| Optical Channels & Distance | 4 Optical Channels × 5 km per channel (Up to 20 km total) | Supports multi-zone cable tunnels, busducts & substation feeders |
| Temperature Measurement Range | -40 °C to +120 °C (High-temperature fiber option up to +150 °C / +300 °C) | Continuous linear thermal profiling along entire fiber length |
| Temperature Accuracy & Resolution | ±1.0 °C accuracy | 0.1 °C display & telemetry resolution | Calibrated for early detection of soil dry-out & cable joint overload |
| Spatial & Alarm Resolution | 0.5 m spot spatial resolution | 1.0 m alarm localization | Pinpoints exact cable joint, rack, or tunnel segment overheating |
| Measurement Cycle Time | Configurable from 2 seconds to 60 seconds per channel | Rapid dT/dt Rate-of-Rise (RoR) & absolute threshold detection |
| Local Display & Status Indicators | Integrated 10.4-inch industrial color touchscreen HMI + 4 LEDs (Run, Fault, Pwr, Alarm) |
Local zone mapping, historical temperature curves, and fault logs |
| Protection Relay Outputs | 16 Programmable Relay Outputs (250 VAC / 3 A or 30 VDC / 3 A) |
Direct hardware inter-trip to fire alarm panels & switchgear relays |
| SCADA & Industrial Protocols | Modbus TCP (RJ45 Ethernet), RS485 Modbus RTU, RS232 | Seamless integration with VTI Gateway GW22-D, IEC 60870-5-104 & IEC 61850 |
| Power Supply & Consumption | DC 24 V (50 W) or 110–240 VAC (50/60 Hz) substation auxiliary supply | Dual redundant power input support for critical substations |
| Enclosure Dimensions & Mounting | 420 × 182 × 580 mm heavy-duty industrial wall-mount / cabinet steel enclosure | Operating ambient: -10 °C to +55 °C, 5%–95% RH non-condensing |
How Does VTI-GL-100C DTS Complement VTI-TS-22 / VTI-TS-26 Wireless Sensors in 110kV–500kV Substations?
Hybrid Substation Architecture: In modern 22kV–500kV substations and hyperscale data centers, engineers combine VTI-TS-22 (TBR22) and VTI-TS-26 (VTI-TS-26) self-powered wireless sensors (>= 1 A, ±0.2 °C) on bolted busbar joints and disconnector blades with the VTI-GL-100C Fiber Optic DTS along underground power cables and transformer windings, unifying all telemetry into the 4-Layer VTI + DewesoftX CBM Platform.